Category
|
Description
|
Hazard
|
Standard
|
Corrective Action
|
VIEW
|
Chemical Hazards |
Conatiners of solvent (acetone) not properly labeled or covered.
|
inhalation skin contact |
1910.106(e)(2)(iv) and 1200(f)
|
Containers were properly labeled as per MSDS and provided covers.
|
VIEW
|
Chemical Hazards |
Containers of solvent and glue not properly labeled
|
inhalation skin contact |
1910.1200(f)
|
Containers were properly labeled as per MSDS
|
VIEW
|
Chemical Hazards |
Employees not trained in lead hazard
|
inhalation ingestion |
1910.1025(l)
|
Lead training added to the employer's soldering certification program
|
VIEW
|
Chemical Hazards |
Spray area not constructed of steel, or of concrete or masonry or aluminum. Spray area was constructed of wood and plastic was lining the walls inside
|
Fire |
1910.107
|
Construct the spray area of steel or concrete, masonry or aluminum.
|
VIEW
|
Chemical Hazards |
Unlabelled container
|
inhalation skin contact ingestion |
1910.1200(f)(5)(i)
|
Properly label chemical container
|