Category
|
Description
|
Hazard
|
Standard
|
Corrective Action
|
VIEW
|
Scaffolds |
Photo shows part of structure used to tie off. |
2 Point Suspension Scaffold -anchor points not evaluated. |
1926.451(d)(3)(ix) |
Engineering firm hired to design, installl and test anchor points for load capacity required. |
VIEW
|
Scaffolds |
Photo shows tie-backs not at 90 degrees |
2 point suspension scaffold tiebacks not at 90 degrees. |
1926.451(d)(3)(X) |
Tie-backs corrected to 90 degrees |
VIEW
|
Scaffolds |
Photo shows lifelines not protected from sharp edges. |
Hazard of lifelines breaking resulting in fall hazard for employees. |
1926.451(g)(3)(i) |
Lifelines relocated to protect against sharp edges. |
VIEW
|
Scaffolds |
Employees working on improperly constructed scaffolding system. |
Employees working on improperly constructed scaffolding system. |
1926.451 |
Proper scaffold system |
VIEW
|
Scaffolds |
Employeees working on inadequate scaffolding. |
Employeees working on inadequate scaffolding. |
1926.451 |
Install appropriate scaffolding system |