15  Photos found for the Scaffolds category.

  Category Description Hazard Standard Corrective Action
VIEW Scaffolds This scaffold was within 10 feet of the overhead powerline with 300 volts to 50KV. Fall Protection 1926.451(f)(6) The scaffold should not be erected, dismantlled, used or altered near energized powerlines.
VIEW Scaffolds Photograph illustrates missing planking and guardrails on tubular welded frame scaffold. Fall from scaffold 1926.451(b) (1) and (g) (4) (i) Each platform on all working levels of scaffolds shall be fully planked or decked. Guardrail system shall be installed along all open sides and ends of the platform.
VIEW Scaffolds Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or adequate firm foundation. Fall from scaffold 1926.451 (c)(2) Properly install base plates and mud sills on scaffolding.
VIEW Scaffolds photo shows scaffolding on concrete blocks Hazard of scaffold collapse due to concrete blocks used on footing 1926.451(c)(2)(iii) remove concrete blocks
VIEW Scaffolds (1) Platform consists of one plank only; (2) Plank is supported by another plank that is supported by a window sill; (3) No fall protection. Fall hazard. 1926.451(b)(1); 1926.451(b)(2); 1926.451(b)(4); 1926.451(g)(1) Provide adequate support for planks. Fully plank platform. Provide fall protection.


PREV


NEXT

Showing records 6 - 10 of 15.