Scaffolds |
This scaffold was within 10 feet of the overhead powerline with 300 volts to 50KV.
|
Fall Protection |
1926.451(f)(6)
|
The scaffold should not be erected, dismantlled, used or altered near energized powerlines.
|
VIEW
|
Scaffolds |
Photograph illustrates missing planking and guardrails on tubular welded frame scaffold. |
Fall from scaffold |
1926.451(b) (1) and (g) (4) (i)
|
Each platform on all working levels of scaffolds shall be fully planked or decked. Guardrail system shall be installed along all open sides and ends of the platform.
|
VIEW
|
Scaffolds |
Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or adequate firm foundation.
|
Fall from scaffold |
1926.451 (c)(2) |
Properly install base plates and mud sills on scaffolding.
|
VIEW
|
Scaffolds |
photo shows scaffolding on concrete blocks |
Hazard of scaffold collapse due to concrete blocks used on footing |
1926.451(c)(2)(iii) |
remove concrete blocks |
VIEW
|
Scaffolds |
(1) Platform consists of one plank only; (2) Plank is supported by another plank that is supported by a window sill; (3) No fall protection. |
Fall hazard. |
1926.451(b)(1); 1926.451(b)(2); 1926.451(b)(4); 1926.451(g)(1) |
Provide adequate support for planks. Fully plank platform. Provide fall protection. |